NYY-J 5x4 mm² from 5 to 50m Ground cable Power cable electrical cable, black
search
  • NYY-J 5x4 mm² from 5 to 50m Ground cable Power cable electrical cable, black
  • NYY-J 5x4 mm² from 5 to 50m Ground cable Power cable electrical cable, black
  • NYY-J 5x4 mm² from 5 to 50m Ground cable Power cable electrical cable, black
  • NYY-J 5x4 mm² from 5 to 50m Ground cable Power cable electrical cable, black
  • NYY-J 5x4 mm² from 5 to 50m Ground cable Power cable electrical cable, black
  • NYY-J 5x4 mm² from 5 to 50m Ground cable Power cable electrical cable, black
  • NYY-J 5x4 mm² from 5 to 50m Ground cable Power cable electrical cable, black
  • NYY-J 5x4 mm² from 5 to 50m Ground cable Power cable electrical cable, black
  • NYY-J 5x4 mm² from 5 to 50m Ground cable Power cable electrical cable, black
  • NYY-J 5x4 mm² from 5 to 50m Ground cable Power cable electrical cable, black
  • NYY-J 5x4 mm² from 5 to 50m Ground cable Power cable electrical cable, black

NYY-J 5x4 mm² from 5 to 50m Ground cable Power cable electrical cable, black

€29.95

€5.99 meter

VAT included Delivery time: 1-3 business days
  • Product type: from 5 to 50m Ground cable NYY-J5x4mm²
  • Inner conductor: solid copper, class 1 according to DIN VDE0296
  • Insulation: PVC mixture YI1 according to DIN VDE0207 part4
  • Core colors: blue, brown, black, white, green-yellow
  • Jacket: mixture YM1 according to VDE0207 part5
  • Outside diameter: approx. 16,50+/-0.5mm
  • Jacket color:black
  • Resistance: conductor resistance 4,61Ohm/km
length: 5m
Quantity

 

privacy policy

 

Shipping

 

Right of withdrawal

From 5 to 50m NYY-J 5x4 mm² underground cable electric power cable OFC MADE IN GERMANY

As an installation line - installation in the ground, concrete, water, indoors, outdoors. Coat mixture YM1.

Direct embedding in vibrated, vibrated or stamped concrete is not permitted.

Can also be used outdoors, provided protection from direct sunlight is guaranteed. The product conforms to the 2006/95 / EC directive (low voltage directive).

Technical data

- short description: PVC - underground cable
- type: NYY-J 5 x 4
- nominal voltage: 600 / 1000V (test voltage 4000V)
- running meter: 5, 10, 15, 20, 25, 30, 35, 40 or 50 m
- Conductor: solid copper, class 1 according to VDE 0296
- Flame retardant: according to VDE 0482-332-1-2 / IEC 60332-1-2
- Core insulation: PVC mixture Yll according to VDE 0207 part 4
- Outside diameter: approx. 16.5 +/- 0.5 mm
- Nominal conductor cross-section: 4 mm
- Core colors: blue, brown, black, white, green-yellow
- Sheath mixture: PVC mixture YM 1 after VDE 0207 part 5
- number of cores: 5
- wall thickness of jacket: approx. 2.00 mm min: 1.80 mm
- jacket color: black
- max. Conductor resistance: 4.61 Ohm / km
- Working temperature: -40 ° C to 70 ° C, when laying -5 ° C to 70 ° C

scope of delivery

- underground cable power cable NYY-J 5 x 4 mm² black, from 5 to 50m length, wire colors: blue, brown, black, white, green-yellow

357810758
10000 Items

Data sheet

colour
wire colors: blue, brown, black, white, green-yellow; Outer jacket: black
cross-section
5 x 4 mm²
length
5m, 10m, 15m, 20m, 25m, 30m, 35m, 40m or 50m
inner core
OFC (100% copper)
profile
round